B e n c h m a r k
Oddy Test Results for samples of White Felt Tape sample as follows:
TEST PROCEDURE: Oddy
These materials were tested for volatile compounds which may
create corrosion in display or storage using a variant of the standard "Oddy
test". The production of volatile compounds was tested by isolating each
sample to be tested in an air-tight glass vessel with polished metal
coupons of lead, copper and silver. Distilled water was included in each
vial to provide high relative humidity and accelerate any chemical
reactions. A control set of coupons was also included. All coupons were
exposed to temperatures of 40oC for a period of forty-eight
days.
After this time period, the coupons were removed and examined
using a bench stereo microscope to assess the extent of corrosion
present on each compared with the controls.
This procedure was augmented by use of the sodium
azide test employing cut fragments of the fabric exposed under glass to
the sodium azide test reagent for 3-4 minutes under the polarizing
light microscope while examining the extent of the reaction under a
glass cover slip.
INTERPRETATION OF RESULTS
Control: no corrosion, oxidation or alteration was noted
on the silver, copper or lead coupons.
Benchmark white felt sample with adhesive backing: no
corrosion was determined to be present on the silver coupon, no
oxidation or alteration was noted on the copper or lead coupons.
Sodium Azide test: no release of nitrogen, from which can be
inferred that reactive sulfur compounds are not present in the material.
CONCLUSIONS
The scientific evaluation indicates that the Benchmark white felt fabric with adhesive backing is safe to use in the display
and storage of works of art. No indications were found in the tests that
the backing adhesive is of poor quality, and this should not provide a
source of corrosion itself.
Requested by Benchmark, Rosemont, N.J. 08556
Oddy Test Results for samples of Black Felt Tape sample as follows:
TEST PROCEDURE: Oddy
These materials were tested for volatile compounds which may
create corrosion in display or storage using a variant of the standard "Oddy
test". The production of volatile compounds was tested by isolating each
sample to be tested in an air-tight glass vessel with polished metal
coupons of lead, copper and silver. Distilled water was included in each
vial to provide high relative humidity and accelerate any chemical
reactions. A control set of coupons was also included. All coupons were
exposed to temperatures of 40oC for a period of forty-eight
days.
After this time period, the coupons were removed and examined
using a bench stereo microscope to assess the extent of corrosion
present on each compared with the controls.
This procedure was augmented by use of the sodium azide test
reagent for 3-4 minutes under the polarizing light microscope while
examining the extent of the reaction under a glass cover slip.
INTERPRETATION OF RESULTS
Control: no corrosion, oxidation or alteration was noted
on the silver, copper or lead coupons.
Benchmark black felt sample with adhesive backing: no
corrosion was determined to be present on the silver coupon, no
oxidation or alteration was noted on the copper or lead coupons.
Sodium Azide test: no release of nitrogen, from which can be
inferred that reactive sulfur compounds are not present in the material.
CONCLUSIONS
The scientific evaluation indicates that the Benchmark
black felt fabric with adhesive backing is safe to use in the display
and storage of works of art. No indications were found in the tests that
the backing adhesive is of poor quality, and this should not provide a
source of corrosion itself.
Requested by Benchmark, Rosemont, N.J. 08556